PT-20 Programming Guide
92
i = read_com(1,c);
if (i) _printf(“char %c received from COM1”,*c);
Includes
#include “SDK.h ”
Description
This routine is used to read one byte from the receive buffer and then
remove it from the buffer. However, if the buffer is empty, no action is taken
and 0 is returned. Use the argument “port” as the connect port which is
chosen to open. You can choose 1(RS232).
Returns
1, available or 0 if buffer is empty
write_com
Purpose
Send a string out through RS232 port
Syntax
int write_com(int port, char *s);
Example call
char s[20]={“Hello World\n”};
write_com(1,s);
Includes
#include “SDK.h ”
Description
This routine is used to send a string through RS232 ports. If any prior
transmission is still in process, it is terminated then the current transmission
resumes. The character string is transmitted one by one until a NULL
character is met. A null string can be used to terminate prior transmission.
Use the argument “port” as the connect port which is chosen to open. You
can choose 1(RS232).
If you select RS-232 and set hardware flow control(CTS/RTS), this function
will wait while data be transmitted.
Returns
-1 : error
Other value: the number of words that success writing into.
USB_Open
Purpose
Initialize and enable USB port.
Syntax
void USB_Open(void);
Example call
USB_Open();
Includes
#include “SDK.h ”
Description
The USB_Open function initializes and enable USB port.
Returns
None
USB_Close
Purpose
To close USB port
Syntax
void USB_Close(void);
Example call
USB_Close();
Includes
#include “SDK.h ”
Description
The USB_Close function disable and suspend USB port.
Returns
None