NOTICE: This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits
5 Programming Programming method Manual (Reading special barcode), DOS command through RS-232 (RS-232 model) Programmable characteristics Code type
6 Programming the ArgoScan 8000 Series Scanner To program the 8000 series scanner, you must scan a series of programming barcode in the correct orde
7 Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue Test only 00 01 02 03 04 05
8 Interface Selection This decoder built-in scanner comes in three models and supports interfaces such as keyboard wedge, RS232 serial, and the lat
9 Exit Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a f
10 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need
11 Exit Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04
12 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs c
13 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01 Power-on simulation Disable Enable 00 01 I
14 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII
Using the ArgoxScan 8000 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along
15 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK 00 01 02 03 Inter-character delay 00-99 (msec)
16 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02
17 Pin Assignments Keyboard Wedge Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC CLK / KB 2 NC GND 3 GND DAT
18 Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: Af
19 Exit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indicatio
20 Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By se
21 Exit Insert data group 1 position 00-63 (00: no insertion) 00-63 00 Insert data group 2 position 00-63 (00: no insertion) 00-63 00 Insert
22 Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code lengt
23 Exit Code length transmission Disable Enable 00 01 Code name transmission Disable Enable 00 01 Case conversion Disable Upper case Lower ca
24 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when the
CONTENTS Chapter 1 Introduction Introduction…………………………..………………. 1 Default Setting.………………………………………. 2 ArgoxScan8000 specification.…………………….. 3 Progr
25 Exit Scanning mode Good-read off Momentary Alternate Timeout off Continue Test only 00 01 02 03 04 05 Stand-by duration 01-99 (second) 01-99
26 Scan Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry. The length is defined as the actual barco
27 Exit Option Bar Code Option Alphanumeric Entry Global min. code length 00-64 00-64 04 Global max.code length 00-64 00-64 63 Inverted
28
29 Exit String Setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters:
30 String Setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix
31 Exit Option Bar Code Option Alphanumeric Entry Preamble characters None 1-22 characters ‘PREAMBLE’ 00-ffH ASCII code Postamble characters
32 UPCA Read: Format Leading Zero Data Digits (11 Digits) Check Digit Check-sum transmission: By setting Enable, checks sum will be transmitted. Tr
33 Exit Check-sum transmission Disable Enable 00 01 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASC
34 UPCA Supplement
Telepen.………………………………………………. 74 Standard 2 of 5 ……………………………………… 76 RSS-14.………………………………………………. 78 RSS-Limited…………………………………..…… 80 RSS-Expanded………………………
35 Exit Truncation/ Expansion None Truncate leading zero Expand to EAN13 00 01 02 Supplement Check Counter 20 The
36 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the
37 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < E >
38 UPCE Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Leading Zero Data Digits (6 Digits) Check
39 Exit Supplement digits None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00 01 02 03 04 05 06 07 Truncation/E
40 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of th
41 Exit Truncate ending 0-15 00-15 00
42 EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement di
43 Exit Code ID setting 00-ffH ASCII code 00-ffH < F > Insert group selection 00-44 00-44 00 Supplement digits None 2 digits 5 digits 2
44 EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the
45 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting Two characters 00-ffH ASCII code 00-ffH, 00-ffH < FF
46 EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Tru
47 Exit Truncation / Expansion Disable Enable 00 01 Truncation / Expansion None Truncate leading zero Expand to EAN13 00 01 02 Expansion
48 Code 39 Read: Format Start “” Data Digits ( Variable) Checksum (Optional) End “” Check-sum verification: The checksum of Code-39 is optiona
49 Exit Check-sum verification Disable Enable 00 01 Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. cod
50 Code 39 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39
51 Exit Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start/end transmission Disable Enable 00 01
52 Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of
53 Exit Check-sum transmission Disable Enable 00 01 Max. code leading 00-64 00-64 00 Min. code leading 00-64 00-64 00 Truncate leading 0-
54 Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Tr
1 Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable
55 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < i > Insert group sele
56 Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of
57 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate lead
58 Codabar Read: Format Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Tra
59 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading
60 Exit Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End patt
61 Exit Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all
62 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
63 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < # > Insert grou
64 Exit Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It w
2 Default setting For each barcode shown as below: V = Enabled as default setting - = Not supported Empty space = Not enabled at default setti
65 Exit Code-93 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is made as the
66 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. C
67 Exit Code ID setting 00-ffH ASCII code 00-ffH < & > Insert group selection 00-44 00-44 00
68 Code-11 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is presented as the
69 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading
70 MSI/Plessey Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The MSI/Plessey has one or two
71 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading
72 UK/Plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum d
73 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading
74 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the
3 AS-8000 Specification Weight 90 g (cable not included) Cable – K/B wedge Straight 2.0 m ArgoScan 8000 series Specification Model AS-8000 series
75 Exit Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15
76 Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check-sum verification: The checksum is made as the sum module 10 of
77 Exit *JAC* Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leadi
78 GS1 DataBar Omnidirectional Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending
79 Exit Code ID setting Insert group selection 00-44 00-44 00 UCC/EAN128 emulation Disable Enable 00 01
80 GS1 DataBar Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPC
81 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL > Insert group selection 00-44 00-44 00 UCC/EAN128 emulation Disable Enable 00
82 GS1 DataBar Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code
83 Exit Min. code length 00-99 00-99 01 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII
84 China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Trunca
4 Connector type Crimp type female connector Case material ABS plastic Cushion material TPR Electrical Input Voltage 5 VDC ± 0.25V Power - Oper
85 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < t > Ins
86 Italian Pharmacode Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39.
87 Exit Min. code length 00-64 00-64 09 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH
88 CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA
89 STANDRAD-25 PARA EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA INTERLEAVED-25 PARA
90 MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA GS1 DATABAR OMNIDIRECTIONAL
91 ASCII Code Table ﹛﹜
92 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8000
93 Exit Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initializat
94 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D
Commenti su questo manuale